Dense bus duct has taken a number of unique measures in terms of safety protection to ensure its safe operation and reliable performance in the electrical system.
1. Insulation material selection
High insulation performance materials: Use high insulation performance materials, such as epoxy resin, polyester film, etc., to ensure good insulation of the bus duct shell and internal conductors to prevent electric shock accidents and short circuits.
Self-extinguishing materials: Select self-extinguishing materials that can automatically extinguish under high temperature or fire conditions to reduce the risk of fire spread.
2. Dustproof and waterproof design
Sealing performance: The sealed structure design is adopted to prevent dust and moisture from entering the bus duct and affecting electrical performance and safety.
IP protection level: According to the requirements of the use environment, select the appropriate IP protection level to improve the dust and water resistance of the bus duct.
3. Grounding and leakage protection
Reliable grounding: Ensure that the bus duct system has a good grounding design to reduce safety hazards caused by poor grounding.
Leakage protection device: Equipped with leakage protection device, real-time monitoring of current leakage, once leakage is detected, immediately cut off the power supply to prevent electric shock accidents.
4. Temperature monitoring
Temperature sensor: Install temperature sensor inside the bus duct to monitor the conductor and ambient temperature in real time to prevent safety problems caused by overheating.
Self-cooling system: Design a self-cooling system to reduce the operating temperature of the bus duct through air flow or other cooling methods to improve safety.
5. Mechanical protection
Sturdy shell: Use sturdy shell materials such as aluminum alloy or steel plate to improve the mechanical strength of the bus duct and prevent external impact and damage.
Shockproof design: Use shockproof design in the installation and connection parts of the bus duct to reduce safety problems caused by vibration and mechanical impact.
6. Fireproof and flame-retardant design
Fireproof shell: Use fireproof shell materials to delay the spread of fire in the event of fire and protect the internal electrical equipment and personnel.
Flame-retardant coating: Apply flame-retardant coating on the shell surface to further improve the fireproof performance of the bus duct.
7. Electromagnetic shielding
Electromagnetic shielding design: Take electromagnetic shielding measures to reduce the impact of electromagnetic interference on surrounding equipment and environment, and improve the electromagnetic compatibility of the system.
Shielding grounding: Ensure good grounding of the electromagnetic shielding system to prevent the impact of electromagnetic interference on electrical systems and equipment.
8. Intelligent monitoring system
Remote monitoring: Equipped with a remote monitoring system, real-time monitoring of the operating status of the bus duct, including current, voltage, temperature and other parameters, timely detection and handling of abnormal conditions.
Fault alarm: Set up a fault alarm mechanism. When the system detects abnormal conditions (such as overload, short circuit, etc.), it automatically issues an alarm and takes corresponding measures.
9. Convenience of maintenance and overhaul
Modular design: The modular design is adopted to facilitate daily maintenance and overhaul, reducing safety hazards caused by inconvenient maintenance.
Quick connector: The quick connector design is used for easy installation and disassembly, improving the reliability and safety of the system.
10. Environmental adaptability
Corrosion-resistant materials: Select corrosion-resistant materials such as stainless steel or galvanized steel plates to improve the durability and safety of the bus duct in corrosive environments.
Weather-resistant design: Weather-resistant design is adopted to ensure the stable operation of bus duct under various climatic conditions (such as high temperature, low temperature, humidity, etc.).
11. Overload protection
Overload protection device: Install overload protection device, when the current exceeds the set value, it will automatically cut off the power supply to prevent overheating and damage of equipment.
Thermal relay: Use thermal relay to monitor the current, once an overload is detected, it will act quickly to protect the system safety.
Dense bus duct has taken a variety of unique measures in safety protection, including high insulation performance materials, dust and waterproof design, reliable grounding and leakage protection, temperature monitoring, mechanical protection, fire and flame retardant design, electromagnetic shielding, intelligent monitoring system, maintenance and repair convenience, environmental adaptability and overload protection. These measures together ensure the safe operation and reliable performance of bus duct in electrical systems, and provide comprehensive safety protection for personnel and equipment.